AQM-03 is designed to measure the concentration of toxic gases SO2, NO2, O3, CO, total volatile organic compounds and the mass concentration of particulate matter in the ambient air.
The devices are equipped with a robust, weatherproof, metal housing. Inside the case, the device consists of measurement units, a power supply and a data processing unit, which includes a software system for remote technical support, data management and analytics. The AQM-03 also contains a battery pack, which allows the device to be kept in working order for 6 hours in the event of a power failure.
​
Technical and metrological characteristics
Name and units of measure of characteristics
Feature value
Measurement range, ppm:
SO2 0 - 10
NO2 0 - 10
O3 0 - 18
CO 0 - 32
Total Volatile Organic Compounds 0 - 25
​
Detection limit, ppb:
SO2 35
NO2 20
O3 20
CO 800
Total Volatile Organic Compounds 100
​
Limits of the reduced error in the range, %:
SO2 (0 - 1 ppm) 15
NO2 (0 - 1 ppm) 15
O3 (0 - 2 ppm) 15
CO (0 - 3 ppm) 15
Total Volatile Organic Compounds (0 – 2.5 ppm) 30
Limits of relative error in the range, %:
SO2 (1 - 10 ppm) 15
NO2 (1 - 10 ppm) 15
O3 (2 - 18 ppm) 15
CO (3 - 32 ppm) 15
Total Volatile Organic Compounds (2.5 - 25 ppm) 30
​
Measurement repeatability (SO2, NO2, O3, CO), 5%
Response time (t 90), s: 60
Particle range, μm 0.5 - 15
Max particle count rate, particles/second 10000
Range of indications, μg/m3
РМ 2.5 0 - 500
РМ 10 0 - 1000
Measurement range, μg/m3
РМ 2.5 20 - 500
РМ 10 20 - 1000
​
Measurement accuracy, % ±50
Supply voltage, V (230 ± 10) %
Power consumption, W, up to 150
Weight, kg, up to 27
​